Design of a steady-state detector for fault detection and diagnosis of a residential air conditioner M Kim, SH Yoon, PA Domanski, WV Payne International journal of refrigeration 31 (5), 790-799, 2008 | 221 | 2008 |
Performance of a residential heat pump operating in the cooling mode with single faults imposed M Kim, WV Payne, PA Domanski, SH Yoon, CJL Hermes Applied thermal engineering 29 (4), 770-778, 2009 | 142 | 2009 |
Effects of non-uniform refrigerant and air flow distributions on finned-tube evaporator performance JM Choi, WV Payne, PA Domanski International Congress Refrigeration, 2003 | 83 | 2003 |
Defrost cycle performance for an air-source heat pump with a scroll and a reciprocating compressor V Payne, DL O'neal International Journal of Refrigeration 18 (2), 107-112, 1995 | 81 | 1995 |
Net-zero and beyond! Design and performance of NIST's net-zero energy residential test facility AH Fanney, V Payne, T Ullah, L Ng, M Boyd, F Omar, M Davis, H Skye, ... Energy and buildings 101, 95-109, 2015 | 74 | 2015 |
Sensitivity analysis of installation faults on heat pump performance PA Domanski, HI Henderson, WV Payne US Department of Commerce, National Institute of Standards and Technology, 2014 | 61 | 2014 |
Residential heat pump heating performance with single faults imposed SH Yoon, WV Payne, PA Domanski Applied thermal engineering 31 (5), 765-771, 2011 | 61 | 2011 |
A comparison of an R22 and an R410a air conditioner operating at high ambient temperatures WV Payne, PA Domanski | 60 | 2002 |
Potential benefits of smart refrigerant distributors WV Payne, PA Domanski William V. Payne, Piotr A. Domanski, 2003 | 55 | 2003 |
Effect of common faults on the performance of different types of vapor compression systems Z Du, PA Domanski, WV Payne Applied thermal engineering 98, 61-72, 2016 | 52 | 2016 |
Evaporation and condensation heat transfer performance of flammable refrigerants in a brazed plate heat exchanger SC Palmer, WV Payne, PA Domanski US Department of Commerce, Technology Administration, National Institute of …, 2000 | 49 | 2000 |
Energy use consequences of ventilating a net-zero energy house LC Ng, WV Payne Applied thermal engineering 96, 151-160, 2016 | 46 | 2016 |
Mass flow characteristics of R-407c through short-tube orifices WV Payne, DL O'Neal ASHRAE transactions 104, 197, 1998 | 45 | 1998 |
Normalized performance parameters for a residential heat pump in the cooling mode with single faults imposed JM Cho, J Heo, WV Payne, PA Domanski Applied Thermal Engineering 67 (1-2), 1-15, 2014 | 42 | 2014 |
Cooling mode fault detection and diagnosis method for a residential heat pump M Kim, SH Yoon, WV Payne, PA Domanski NIST Special Publication 1087, 2008 | 40 | 2008 |
Multiphase flow of refrigerant 410A through short tube orifices WV Payne, DL O'Neal ASHRAE transactions 105, 66, 1999 | 38 | 1999 |
Impact of the suction line accumulator on the frost/defrost performance of an air-source heat pump with a scroll compressor DW Nutter, D ONeal, WV Payne American Society of Heating, Refrigerating and Air-Conditioning Engineers …, 1996 | 38 | 1996 |
Development of the reference model for a residential heat pump system for cooling mode fault detection and diagnosis M Kim, SH Yoon, WV Payne, PA Domanski Journal of mechanical science and technology 24, 1481-1489, 2010 | 37 | 2010 |
Mass flow rate of R-410A through short tubes working near the critical point Y Kim, V Payne, J Choi, P Domanski International journal of refrigeration 28 (4), 547-553, 2005 | 31 | 2005 |
A mass flow rate correlation for refrigerants and refrigerant mixtures flowing through short tubes V Payne, DL O'Neal Hvac&R Research 10 (1), 73-87, 2004 | 31 | 2004 |