Frank Knoefel
Frank Knoefel
Sen Investigator, Bruyère Research Institute; uOttawa; Carleton U; AGEWELL SAM3 NIH
bruyere.org üzerinde doğrulanmış e-posta adresine sahip
Başlık
Alıntı yapanlar
Alıntı yapanlar
Yıl
State of the art in geriatric rehabilitation. Part I: review of frailty and comprehensive geriatric assessment
JL Wells, JA Seabrook, P Stolee, MJ Borrie, F Knoefel
Archives of physical medicine and rehabilitation 84 (6), 890-897, 2003
317*2003
Integration of smart home technologies in a health monitoring system for the elderly
A Arcelus, MH Jones, R Goubran, F Knoefel
21st International Conference on Advanced Information Networking and …, 2007
1872007
Medical comorbidity and rehabilitation efficiency in geriatric inpatients
L Patrick, F Knoefel, P Gaskowski, D Rexroth
Journal of the American Geriatrics Society 49 (11), 1471-1477, 2001
1782001
Privacy versus autonomy: a tradeoff model for smart home monitoring technologies
D Townsend, F Knoefel, R Goubran
2011 Annual International Conference of the IEEE Engineering in Medicine and …, 2011
1122011
State of the art in geriatric rehabilitation. Part II: clinical challenges
JL Wells, JA Seabrook, P Stolee, MJ Borrie, F Knoefel
Archives of physical medicine and rehabilitation 84 (6), 898-903, 2003
1062003
Determination of sit-to-stand transfer duration using bed and floor pressure sequences
A Arcelus, CL Herry, RA Goubran, F Knoefel, H Sveistrup, M Bilodeau
IEEE transactions on biomedical engineering 56 (10), 2485-2492, 2009
802009
Identifying movement onset times for a bed-based pressure sensor array
MH Jones, R Goubran, F Knoefel
IEEE International Workshop on Medical Measurement and Applications, 2006 …, 2006
722006
Feature extraction for the differentiation of dry and wet cough sounds
H Chatrzarrin, A Arcelus, R Goubran, F Knoefel
2011 IEEE international symposium on medical measurements and applications …, 2011
602011
Measurements of sit-to-stand timing and symmetry from bed pressure sensors
A Arcelus, I Veledar, R Goubran, F Knoefel, H Sveistrup, M Bilodeau
IEEE Transactions on instrumentation and measurement 60 (5), 1732-1740, 2011
532011
Lying and sitting posture recognition and transition detection using a pressure sensor array
N Foubert, AM McKee, RA Goubran, F Knoefel
2012 IEEE International Symposium on Medical Measurements and Applications …, 2012
512012
Reliable respiratory rate estimation from a bed pressure array
MH Jones, R Goubran, F Knoefel
2006 International Conference of the IEEE Engineering in Medicine and …, 2006
502006
Recommendations for the use of serious games in neurodegenerative disorders: 2016 Delphi Panel
V Manera, G Ben-Sadoun, T Aalbers, H Agopyan, F Askenazy, M Benoit, ...
Frontiers in psychology 8, 1243, 2017
452017
Relative thresholding with under-mattress pressure sensors to detect central apnea
D Townsend, M Holtzman, R Goubran, M Frize, F Knoefel
IEEE Transactions on Instrumentation and Measurement 60 (10), 3281-3289, 2011
452011
Event-related Potentials elicited during Working Memory are altered in Mild Cognitive Impairment
F Lopez Zunini, Rocio, Knoefel, F Lord, Courtney, Dzual, M Breau, ...
International Journal of Psychophysiology 109, 1-8, 2016
352016
Dual-stiffness flooring: can it reduce fracture rates associated with falls?
F Knoefel, L Patrick, J Taylor, R Goubran
Journal of the American Medical Directors Association 14 (4), 303-305, 2013
342013
Measuring variation in driving habits between drivers
B Wallace, R Goubran, F Knoefel, S Marshall, M Porter
2014 IEEE International Symposium on Medical Measurements and Applications …, 2014
332014
Validation of unobtrusive pressure sensor array for central sleep apnea screening
D Townsend, R Goubran, F Knoefel, J Leech
IEEE Transactions on Instrumentation and Measurement 61 (7), 1857-1865, 2012
332012
Driver identification using vehicle acceleration and deceleration events from naturalistic driving of older drivers
NC Fung, B Wallace, ADC Chan, R Goubran, MM Porter, S Marshall, ...
2017 IEEE International Symposium on Medical Measurements and Applications …, 2017
312017
Measurement of torso movement with delay mapping using an unobtrusive pressure-sensor array
DI Townsend, M Holtzman, R Goubran, M Frize, F Knoefel
IEEE Transactions on Instrumentation and Measurement 60 (5), 1751-1760, 2010
312010
Context-aware smart home monitoring through pressure measurement sequences
A Arcelus, R Goubran, H Sveistrup, M Bilodeau, F Knoefel
2010 IEEE International Workshop on Medical Measurements and Applications, 32-37, 2010
272010
Sistem, işlemi şu anda gerçekleştiremiyor. Daha sonra yeniden deneyin.
Makaleler 1–20