Proposal for Standard Compact Server Model for Transient Data Center Simulations RRS Zachary M. Pardey, Dustin W. Demetriou, Hamza Salih Erden, James ... ASHRAE Transactions 121 (1), 2015 | 26 | 2015 |
Transient thermal response of servers through air temperature measurements HS Erden, HE Khalifa, RR Schmidt ASME 2013 International Technical Conference and Exhibition on Packaging and …, 2013 | 21 | 2013 |
Design of simulated server racks for data center research JF Smith, WA Abdelmaksoud, HS Erden, JF Dannenhoffer, TQ Dang, ... International Electronic Packaging Technical Conference and Exhibition 44625 …, 2011 | 15 | 2011 |
Experimental Demonstration and Flow Network Model Verification of Induced CRAH Bypass for Cooling Optimization of Enclosed-Aisle Data Centers HS Erden, M Koz, MT Yildirim, HE Khalifa IEEE Transactions on Components, Packaging and Manufacturing Technology 7 …, 2017 | 13 | 2017 |
Determination of the lumped-capacitance parameters of air-cooled servers through air temperature measurements H Salih Erden, H Ezzat Khalifa, RR Schmidt Journal of Electronic Packaging 136 (3), 2014 | 13 | 2014 |
A hybrid lumped capacitance-CFD model for the simulation of data center transients HS Erden, HE Khalifa, RR Schmidt HVAC&R Research 20 (6), 688-702, 2014 | 12 | 2014 |
Worldwide energy analysis of major free cooling methods for data centers O Gözcü, B Özada, MU Carfi, HS Erden 2017 16th IEEE Intersociety Conference on Thermal and Thermomechanical …, 2017 | 11 | 2017 |
Experimental investigation of CRAH bypass for enclosed aisle data centers HS Erden, MT Yildirim, M Koz, HE Khalifa 2016 15th IEEE Intersociety Conference on Thermal and Thermomechanical …, 2016 | 10 | 2016 |
Development of an IT equipment lumped capacitance parameter database for transient data center simulations DW Demetriou, HS Erden, HE Khalifa, RR Schmidt Fourteenth Intersociety Conference on Thermal and Thermomechanical Phenomena …, 2014 | 9 | 2014 |
Optimization of Enclosed Aisle Data Centers With Induced CRAH Bypass HS Erden, M Koz, MT Yildirim, HE Khalifa IEEE Transactions on Components, Packaging and Manufacturing Technology 7 …, 2017 | 8 | 2017 |
Energy assessment of CRAH bypass for enclosed aisle data centers HS Erden, MT Yildirim, M Koz, HE Khalifa 2016 15th IEEE Intersociety Conference on Thermal and Thermomechanical …, 2016 | 8 | 2016 |
Experimental and analytical investigation of the transient thermal response of air cooled data centers HS Erden | 8 | 2013 |
Energy and economic assessment of major free cooling retrofits for data centers in Turkey O GÖZCÜ, HS ERDEN TURKISH JOURNAL OF ELECTRICAL ENGINEERING & COMPUTER SCIENCES 27 (3), 2097-2212, 2019 | 7 | 2019 |
Room-level transient CFD modeling of rack shutdown HS Erden, HE Khalifa, RR Schmidt International Electronic Packaging Technical Conference and Exhibition 55768 …, 2013 | 7 | 2013 |
Energy and environmental assessment of on-site power and cooling for data centers HS Erden, HE Khalifa HVAC&R Research 18 (1-2), 51-66, 2012 | 7 | 2012 |
Parameter estimation for lumped capacitance modeling of CRAH units during chilled water interruption HS Erden, HE Khalifa International Electronic Packaging Technical Conference and Exhibition 56888 …, 2015 | 6 | 2015 |
Numerical investigation of the melting of a phase change material in a thermal storage device with embedded air flow channels M Koz, HS Erden, HE Khalifa ASME 2016 Heat Transfer Summer Conference collocated with the ASME 2016 …, 2016 | 4 | 2016 |
Investigation of CRAH bypass for air-cooled data centers using computational fluid dynamics VE Ahmadi, HS Erden 2018 IEEE International Telecommunications Energy Conference (INTELEC), 1-6, 2018 | 2 | 2018 |
A parametric CFD study of computer room air handling bypass in air-cooled data centers VE Ahmadi, HS Erden Applied Thermal Engineering 166, 114685, 2020 | 1 | 2020 |
Investigation of induced CRAH bypass for air-cooled data centers using computational fluid dynamics HS Erden 2017 25th International Conference on Software, Telecommunications and …, 2017 | 1 | 2017 |