Takip et
Mustafa Kocakulak
Mustafa Kocakulak
İzmir Demokrasi Üniversitesi Biyomedikal Mühendisliği Bölümü
idu.edu.tr üzerinde doğrulanmış e-posta adresine sahip - Ana Sayfa
Başlık
Alıntı yapanlar
Alıntı yapanlar
Yıl
Bilirubin removal from human plasma in a packed-bed column system with dye-affinity microbeads
A Denizli, M Kocakulak, E Pişkin
Journal of Chromatography B: Biomedical Sciences and Applications 707 (1-2 …, 1998
991998
Clinical performance and biocompatibility of poly (2-methoxyethylacrylate)—coated extracorporeal circuits
S Gunaydin, B Farsak, M Kocakulak, T Sari, C Yorgancioglu, Y Zorlutuna
The Annals of thoracic surgery 74 (3), 819-824, 2002
592002
Engineering long shelf life multi-layer biologically active surfaces on microfluidic devices for point of care applications
W Asghar, M Yuksekkaya, H Shafiee, M Zhang, MO Ozen, F Inci, ...
Scientific reports 6 (1), 1-10, 2016
582016
Bilirubin Removal from Human Plasma with Albumin Immobilised Magnetic Poly (2‐hydroxyethyl methacrylate) Beads
AY Rad, H Yavuz, M Kocakulak, A Denizli
Macromolecular Bioscience 3 (9), 471-476, 2003
562003
New sorbent for bilirubin removal from human plasma: Cibacron Blue F3GA-immobilized poly (EGDMA–HEMA) microbeads
M Kocakulak, A Denizli, AY Rad, E Pişkin
Journal of Chromatography B: Biomedical Sciences and Applications 693 (2 …, 1997
521997
Pulsatile flow improves renal function in high-risk cardiac operations
M Kocakulak, G Aşkin, S Küçükaksu, O Tarcan, E Pişkin
Blood purification 23 (4), 263-267, 2005
482005
Specific sorbents for bilirubin removal from human plasma: Congo red‐modified poly (EGDMA/HEMA) microbeads
A Denizli, M Kocakulak, E Pişkin
Journal of applied polymer science 68 (3), 373-380, 1998
361998
Comparison of pulsatile and non-pulsatile cardiopulmonary bypass in patients with chronic obstructive pulmonary disease
O Tarcan, MA Özatik, A Kale, A Akgül, M Kocakulak, M Balci, A Ündar, ...
Medical Science Monitor 10 (7), CR294-CR299, 2004
322004
Effect of poly (2-methoxyethyl acrylate)-coated oxygenators on haemolysis
M Kocakulak, T Özgürtaş, H Ayhan
Journal of Biomaterials Science, Polymer Edition 17 (4), 449-460, 2006
212006
Alkali blue 6B-derivatized poly (EGDMA/HEMA) microbeads for bilirubin removal from human plasma
A DENIZLI*, M Kocakulak, E Kskin
Journal of Macromolecular Science, Part A: Pure and Applied Chemistry 35 (1 …, 1998
181998
Investigation of blood compatibility of PMEA coated extracorporeal circuits
M Kocakulak, C Kocum, R Saber, H Ayhan, S Günaydin, T Sari, ...
Journal of bioactive and compatible polymers 17 (5), 343-356, 2002
112002
Clinical significance of strategic leukocyte filtration in different risk cohorts undergoing cardiac surgery
S Gunaydin, K McCusker, V Vijay, T Sari, MF Sargon, MA Onur, ...
Filtration 1 (2), 95-106, 2005
82005
Pulsatile roller pump perfusion is safe in high risk patients
M Kocakulak, S Küçükaksu, E Pişkin
The International journal of artificial organs 27 (5), 433-439, 2004
82004
Clinical evaluation strategic leukofiltration with surface modification: enhanced preservation or fantasy
S Gunaydin, T Sari, K McCUSKER, V Vijay, H Aydin, B Farsak, ...
Filtration 1 (1), 57-67, 2005
72005
Humoral immune response and coated or uncoated oxygenators during cardiopulmonary bypass surgery
SO Karakisi, Ş Bozok, Ş Ergene, G İlhan, H Karamustafa, N Tufekci, ...
Cardiovascular journal of Africa 27 (4), 242, 2016
52016
Investigation of inflammatory response at blood–poly (2-methoxyethyl acrylate) (PMEA) interface in vivo via scanning tunneling microscope
M Kocakulak, İC Koçum, H Ayhan
Journal of bioactive and compatible polymers 27 (1), 45-53, 2012
52012
QCM biosensor for testing the inflammatory response to blood-contacting biomaterials
E Haberal, N Ugur, M Kocakulak
Artificial cells, nanomedicine, and biotechnology 41 (3), 222-226, 2013
42013
Construction of a bilirubin biosensor based on an albumin-immobilized quartz crystal microbalance
M Kocakulak, T Bayrak, S Saglam
Biocybernetics and Biomedical Engineering 37 (3), 611-617, 2017
32017
Bilirubin removal from human plasma, in a packed-bed column system with dye affinity microbeds
D Adil, K Mustafa, P Erhan
J Chromatogr B 707 (1-2), 25-31, 1998
31998
Investigation of blood compatibility and determination of clinical performance of PMEA coated and flow optimized oxygenator
U Demirkilic, E Kuralay, H Tatar, M Kocakulak, C Kocum, H Ayhan
Journal of bioactive and compatible polymers 19 (5), 395-408, 2004
22004
Sistem, işlemi şu anda gerçekleştiremiyor. Daha sonra yeniden deneyin.
Makaleler 1–20