Electrochemical biosensors: recommended definitions and classification DR Thévenot, K Toth, RA Durst, GS Wilson Biosensors and bioelectronics 16 (1-2), 121-131, 2001 | 2581 | 2001 |
Biosensors: fundamentals and applications A Turner, I Karube, GS Wilson Oxford university press, 1987 | 2180 | 1987 |
Implantable glucose sensor GS Wilson, DS Bindra, BS Hill, DR Thevenot, R Sternberg, G Reach, ... US Patent 5,165,407, 1992 | 1564 | 1992 |
Rotating ring-disk enzyme electrode for biocatalysis kinetic studies and characterization of the immobilized enzyme layer RA Kamin, GS Wilson Analytical Chemistry 52 (8), 1198-1205, 1980 | 1301 | 1980 |
Electrochemical biosensors: recommended definitions and classification DR Thevenot, K Toth, RA Durst, GS Wilson Pure and applied chemistry 71 (12), 2333-2348, 1999 | 1104 | 1999 |
Design and in vitro studies of a needle-type glucose sensor for subcutaneous monitoring DS Bindra, Y Zhang, GS Wilson, R Sternberg, DR Thevenot, D Moatti, ... Analytical Chemistry 63 (17), 1692-1696, 1991 | 943 | 1991 |
Biosensors for real-time in vivo measurements GS Wilson, R Gifford Biosensors and Bioelectronics 20 (12), 2388-2403, 2005 | 882 | 2005 |
Study and development of multilayer needle-type enzyme-based glucose microsensors R Sternberg, MB Barrau, L Gangiotti, DR Thévenot, DS Bindra, GS Wilson, ... Biosensors 4 (1), 27-40, 1989 | 871 | 1989 |
Progress toward the development of an implantable sensor for glucose GS Wilson, Y Zhang, G Reach, D Moatti-Sirat, V Poitout, DR Thévenot, ... Clinical Chemistry 38 (9), 1613-1617, 1992 | 820 | 1992 |
Can continuous glucose monitoring be used for the treatment of diabetes G Reach, GS Wilson Analytical chemistry 64 (6), 381A-386A, 1992 | 809 | 1992 |
Measurement of pH. Definition, standards, and procedures (IUPAC Recommendations 2002) RP Buck, S Rondinini, AK Covington, FGK Baucke, CMA Brett, ... Pure and applied chemistry 74 (11), 2169-2200, 2002 | 733 | 2002 |
A glucose monitoring system for on line estimation in man of blood glucose concentration using a miniaturized glucose sensor implanted in the subcutaneous tissue and a wearable … V Poitout, D Moatti-Sirat, G Reach, Y Zhang, GS Wilson, F Lemonnier, ... Diabetologia 36, 658-663, 1993 | 712 | 1993 |
Enzyme-based biosensors for in vivo measurements GS Wilson, Y Hu Chemical reviews 100 (7), 2693-2704, 2000 | 654 | 2000 |
Recent developments in faradaic bioelectrochemistry FA Armstrong, GS Wilson Electrochimica Acta 45 (15-16), 2623-2645, 2000 | 586 | 2000 |
Towards continuous glucose monitoring: in vivo evaluation of a miniaturized glucose sensor implanted for several days in rat subcutaneous tissue D Moatti-Sirat, F Capron, V Poitout, G Reach, DS Bindra, Y Zhang, ... Diabetologia 35, 224-230, 1992 | 501 | 1992 |
Elimination of the acetaminophen interference in an implantable glucose sensor Y Zhang, Y Hu, GS Wilson, D Moatti-Sirat, V Poitout, G Reach Analytical Chemistry 66 (7), 1183-1188, 1994 | 452 | 1994 |
In vitro and in vivo evaluation in dogs of a miniaturized glucose sensor V POITOUT, D MOATTI, G VELHO, G REACH, R STERNBERG, ... ASAIO Journal 37 (3), M298-M300, 1991 | 409 | 1991 |
Surface-modified electrochemical detector for liquid chromatography G Sittampalam, GS Wilson Analytical Chemistry 55 (9), 1608-1610, 1983 | 409 | 1983 |
Reduction of acetaminophen interference in glucose sensors by a composite Nafion membrane: demonstration in rats and man D Moatti-Sirat, V Poitout, V Thome, MN Gangnerau, Y Zhang, Y Hu, ... Diabetologia 37, 610-616, 1994 | 401 | 1994 |
A user-friendly method for calibrating a subcutaneous glucose sensor-based hypoglycaemic alarm B Aussedat, V Thome-Duret, G Reach, F Lemmonier, JC Klein, Y Hu, ... Biosensors and Bioelectronics 12 (11), 1061-1070, 1997 | 390 | 1997 |